When assembling or repairing audio amplifiers, it is not uncommon for it to be necessary to adjust the level of the signal supplied to this amplifier, while it is not always possible or desirable to organize a RG (volume control) on a potentiometer or discrete regulator. In this case, the module on the PT2256 microcircuit will help, which is an electronic volume control with 2 buttons: "+" and "-".
An additional "feature" of this RG is loudness, with a cutoff of up to 20 dB at a frequency of 1 kHz
Harmonic distortion factor
THD 0.01%
Signal-to-noise ratio ≥ 90dB
Measurements
Supply voltage DC 12V
Frequency response (from 40 Hz to 15 kHz), dB +0.94, -1.09
Noise level, dB (A) -96,3
Dynamic range, dB (A) 96,4
THD, % 0,0250
THD + Noise, dB (A) -69,7
IMD + Noise, % 0,1850
Stereo crosstalk, dB -71,9
IMD at 10 kHz, % 0,0230
Measurement Page

Measurement of characteristics. PT2256 Volume Control Testing

General characteristics
Built-in protection No
Chip PT2256
Entrance level 03-3,5V
Module size LxWxH, mm

25x50x15

Number of channels stereo
Supply voltage maximum (constant) DC 12V
Supply voltage minimum (constant) DC 5V
Weight, kg

0,014

Write a review

Note: HTML is not translated!
    Bad           Good
Captcha

Electronic volume control PT2256 with loudness

  • Brands kitON
  • Product Code: RG56-01
  • Availability: In Stock
  • 360.00грн.


Related Products

Tags: VOLUME CONTROL, AFC CORRECTION, LOUDENESS

Products viewed

4.2V Li-Ion Charge Module with Protection, Type-C

4.2V Li-Ion Charge Module with Protection, Type-C

Universal charge module for Li-Ion batteries with current up to 1A. The TP4056 chip is used in stand..

110.00грн.

Thermostat programmable, -50 ~ + 110C

Thermostat programmable, -50 ~ + 110C

The digital temperature controller is designed to automatically control the current ambient temperat..

0.00грн.

Featured Articles

Measurement technique

Measurement technique

Any more or less complex electronic device requires a functional check and adjustmentThe audio power amplifier is no exception and measurements of the characteristics of this device are not only a dev..

Volume control PT2256 measurement

Volume control PT2256 measurement

Testing device Volume control PT2256 Sampling mode 24-bit, 48 kHz Interface E-MU1616m Testing chain E-MU1616m>Volume control PT2256>E-MU1616m Supply v..